Product offer - Multifunctional relays for Power Engineering

 

The automation and protection set depends on the analog channel configuration and is limited by the maximum number of iZAZ350 software configuration objects. In the software version, you can select a set from the basic application library and individually configure the required group of protection functions. Depending on the case version, you can use 1 to 4 analog input modules; each module has 8 current or voltage inputs (maximum 32 analog measurement inputs). The following standard hardware versions of analog input modules are available:

A - current-voltage: I13f, 3Io, U13f, 3Uo
B - current: I13f, I23f, I3, I4
C - voltage: U13f, U23f, U3, U4

The details on the availability of functions in certain hardware variants are listed in Table 1. CATALOG CARD (PDF 1,1 MB).

Protective function and automatic control library

  • Overcurrent (50/51)
  • Inverse-time overload overcurrent (51)
  • Peak overcurrent (wide frequency range) (50/51)
  • Inverse-time rotor overcurrent (49R)
  • Thermal overcurrent (49M)
  • Negative-sequence overcurrent (unbalance) (46)
  • Inverse-time negative-sequence overcurrent (unbalance) (46)
  • Undercurrent (37)
  • Overcurrent with directional blocking (67)
  • Three-stage overvoltage (59)
  • Peak overvoltage (wide frequency range) (59)
  • Three-stage undervoltage (27)
  • Two-stage zero-sequence overvoltage (59N)
  • Negative-sequence overvoltage (47)
  • Positive-sequence undervoltage (27D)
  • Rate-of-change voltage (59S/27S)
  • Incremental voltage (59SA/27SA)
  • Integral voltage (59SI/27SI)
  • Two-stage earth-fault overcurrent (50N/51N)
  • Inverse-time earth-fault overcurrent (51N)
  • Two-stage directional earth-fault (MV) (59N/67N)
  • Two-stage directional earth-fault (HV) (59N/67N)
  • Non-directional admittance earth-fault (21N/67N)
  • Directional conductance earth-fault (0÷90) ° (21N/67N)
  • Directional susceptance earth-fault (0÷90) ° (21N/67N)
  • Frequency (81O/81U)
  • Rate-of-change of frequency (81S)
  • Incremental rate-of-frequency-change (81SA)
  • Overexcitation (24)
  • Directional power supervision, reverse power (32R)
  • Directional power supervision, low forward power (32L)
  • External bistable signal (62)
  • Load-jam motor (51LR)
  • Starting-time supervision (48)
  • Startup monitoring (66)
  • Rotor stall monitoring (51LR)
  • Phase-sequence voltage (47)
  • Loss-of-excitation (40/27)
  • Underimpedance (21)
  • Against switch on non-excited generator (50/27)
  • Loss-of-synchronism (RMS current pulsations) (51S)
  • Diffe rential (generator, transformer, generator-transformer blocks), blocking for 2nd and 5th (87G/87T/87B)
  • Line differential (two half-sets) (87L)
  • Distance (five zones, polygonal or MHO impedance charactic) (21)
  • Fault location function (LMZ)
  • Power swing blocking function (68/68T)
  • Restricted earth fault differential REF (IL1+IL2+IL3-3Io) (64REF)
  • Ground-fault for rotor (64R)
  • 100% generator stator ground-fault (3rd harmonics difference) (64S)
  • Out-of-Step (slipping pole) (78)
  • Power factor monitoring tgφ (55)
  • Automatic underfrequency load shedding (81U)
  • Automatic Reclosing (79)
  • Automatic Transfer Switch (83)
  • Automatic planned transfer switch (83)
  • Automatic undervoltage load shedding (27)
  • Local breaker failure (50BF)
  • Tap changer control (voltage regulator) (90)
  • Synchrocheck (25)
  • Tester for rotor cages of induction motors
  • Detection of cable insulation failures
  • Auto matic generator synchronization (25A)
  • Forcing of the active component of earth-fault current
  • Capacitor bank switching control